P4000 Specifications:

  • Pump Design: Dual in-line piston, pulseless design. Micro-stepped motor control. Floating piston bayonet-mounted heads. Patented ceramic check valves.
  • Flow accuracy: ±0.5% at 1 ml/min with water, after liquid end calibration.
  • Flow precision: <0.2% RSD
  • Flow Range: 0.01 to 10 ml/min standard. Settable in 0.01 ml/min increments.
  • Composition Repeatability: 0.2% RSD
  • Gradient Linearity: ±0.5% from 10-90% composition
  • Maximum Pressure: 6000 psi, 420 bar, 42MPa with standard heads
  • Wetted Surfaces: Stainless steel or PEEK, titanium, ceramic, sapphire, Teflon, Tefzel, and polyethylene
  • Pressure Pulsation: <2% amplitude; <1% typical at 1ml/min water or methanol at >500 psi
  • Delay Volume: <0.6ml
  • Compressibility Compensation: Automatic
  • Shutdown File: Protected in non-volatile memory
  • Flow Stability Test: Pump flow diagnostic to verify proper pump performance
  • Diagnostics: Diagnostic tests to verify proper electrical and mechanical operation
  • Communications: Hardwire external events connector. Run and Stop remote inputs; Ready, Run, Timed Event and Analog Pressure outputs. SCM400 degas communication port.
  • Ambient Environment: 10-40°C, 5-95% relative humidity, noncondensing.

AS 3000 Autosampler Specifications:

  • Vial capacity:
    • 120 vials in three removable trays
    • 105 vials with tray temperature control
  • Variable-Volume:
    • Injection Precision: <0.5 % RSD @ 10 pL or greater
    • Injection Volume: 0.1 - 100 pL injection standard (250 uL syringe) up to 1000 uL injections with larger loops and syringes
  • Fixed-Loop:
    • Injection Precision: <0.5% RSD @ 10 uL or greater
    • Injection Volume: 20 uL standard (250 uL syringe) 1000 uL injections with larger loops and syringes
  • Sample Carryover:
    • <0.0 I% at 300 gL flush volume
    • 5 mL flush volumes can be set
  • Minimum Sample Volume: 1 uL can be injected from 5 uL with an end-port needle
  • Needle Height: Programmable in 0.1 mm increments
  • Method Files: Protected in non-volatile memory
  • Communications
    • Remote Inputs: Pump Ready, Inject Hold
    • Outputs Pump Stop, Autosampler Ready, Inject, Gradient Start, Four timed-event outputs
    • SpectraNETIRS-232 port
  • Ambient Environment: 10° - 40°C, 5 - 95% relative humidity
  • Dimensions: 37cm x 41cm x 51cm (HxWxD)

This used TSP P 4000 Pump and AS 3000 Autosampler HPLC System is really in a great shape and tested at SpectraLab Scientific. 90 days warranty included.


We are professional to the stuffs. Please call us.


Multiple avaialble

[Home] [What's New] [About Us] [Products] [Site Map] [Ordering Information] [Cooperation] [Pre-owned Equipment ] [Career]

Copyright 2010 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com